<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: Recent Radio Show</title>
	<atom:link href="http://www.strawbale.com/recent-radio-show/feed" rel="self" type="application/rss+xml" />
	<link>http://www.strawbale.com/recent-radio-show</link>
	<description>The World's Leader in Straw Bale Education</description>
	<lastBuildDate>Wed, 10 Mar 2010 22:17:42 -0700</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.1</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>By: Andrew</title>
		<link>http://www.strawbale.com/recent-radio-show/comment-page-1#comment-1197</link>
		<dc:creator>Andrew</dc:creator>
		<pubDate>Mon, 11 Feb 2008 01:22:08 +0000</pubDate>
		<guid isPermaLink="false">http://www.strawbale.com/recent-radio-show#comment-1197</guid>
		<description>The reason for this is that the strength of the bales in the out of plane direction (perpendicular to the wall) is limited to a wall width to height ratio.  If you go too high, the wall becomes weak under the load of the roof and can collapse.  It is possible to build a single story with a loft if the roof pitch is steep.  I am sure people have done multiple story load bearing houses, but it is very experimental and somewhat dangerous at this point.  There is a lot to do in terms of testing before I would recommend anyone do it.  Thanks for the question.</description>
		<content:encoded><![CDATA[<p>The reason for this is that the strength of the bales in the out of plane direction (perpendicular to the wall) is limited to a wall width to height ratio.  If you go too high, the wall becomes weak under the load of the roof and can collapse.  It is possible to build a single story with a loft if the roof pitch is steep.  I am sure people have done multiple story load bearing houses, but it is very experimental and somewhat dangerous at this point.  There is a lot to do in terms of testing before I would recommend anyone do it.  Thanks for the question.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Mona</title>
		<link>http://www.strawbale.com/recent-radio-show/comment-page-1#comment-1174</link>
		<dc:creator>Mona</dc:creator>
		<pubDate>Sat, 09 Feb 2008 16:31:47 +0000</pubDate>
		<guid isPermaLink="false">http://www.strawbale.com/recent-radio-show#comment-1174</guid>
		<description>You have said numerous times that you can&#039;t build 2-story load bearing, but I&#039;ve come across (in books and on the web) houses that were 2-story and load bearing.  Why do you say it isn&#039;t/can&#039;t be done?</description>
		<content:encoded><![CDATA[<p>You have said numerous times that you can&#8217;t build 2-story load bearing, but I&#8217;ve come across (in books and on the web) houses that were 2-story and load bearing.  Why do you say it isn&#8217;t/can&#8217;t be done?</p>
]]></content:encoded>
	</item>
</channel>
</rss>
